CONTENTS
1.0 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 002
1.1 Complete Kit
2.0 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 03
2.1 Key Function
2.2 Main Display
3.0 Accessing Secondary Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
05
3.1 Function Table
3.2 Changing the value of the selected function
3.3 Moving through the Function Modes
4.0 Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 08
4.1 Preparing for testing
4.2 Changing the Units of Measure
4.3 Selecting the Measuring Mode
4.4 Comparator functions
4.5 Setting the HI and LOW values
4.6 Zero Function
4.7 Saving data in memory
4.8 Recalling stored memory
4.9 Clearing stored data
5.0 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
6.0 Dimensional Drawings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
7.0 Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
- 16 -
6.0 DIMENSION DRAWINGS
OI308TNP
Vista de página 0
1 2 3 4 5 6 7 8 9 10

Resumo do Conteúdo

Página 1 - CONTENTS

- 1 -CONTENTS1.0 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0021.1 Co

Página 2 - Torque Ranges

CAP-TNPDIGITAL CAP TORQUE TESTEROperating InstructionsCHECK•LINE®BY ELECTROMATICELECTROMATIC E Q U I P M E N T C O., I N C.600 Oakland Ave., Cedarhur

Página 3

- 2 -1.0 INTRODUCTIONThank you for choosing the CAP-TNP digital torque tester, with proper care this unit will provide many years of reliable service.

Página 4

- 3 -2.0 OVERVIEW2.1 Key functionsPower key Turns the gauge ON and OFF.Recall keyRecall data stored in OPEN and CLOSe modes.NOTE: in AVERAGE or MEAN m

Página 5 - CCESSING SECONDARY FUNCTIONS

- 4 -2.2 Main DisplayUnits/Status indicator – located on the upper part of the display, thisshows the current units of measure selected for the torque

Página 6

- 5 -3.0 ACCESSING SECONDARY FUNCTIONSOperation Key OperationHow To OperateZero/RST PowerFunction Mode1. With Power off, press and hold the Zero/RST

Página 7

- 6 -3.1 Function Mode TableFUNCTIONSub displayOptions Initial SettingMeasuring Unit F01Changes units of measure: N.m, N.cm, Kg.cm, Lb.inN.mFunction M

Página 8 - PERATION

- 7 -NOTE: Use the MODE key to changes values of each function. Use theZero/RST key to move to the next function.- 10 -4. Press the Zero/RST key until

Página 9

- 8 -4.0 OPERATION4.1 Preparing for testing1. Determine the size of the sample to be tested. Adjust the 4-pin jig on the testing table accordingly. 2.

Página 10 - ELECTROMATIC

7.0 WARRANTYELECTROMATIC Equip’t Co., Inc. expressly warrants to its buyer for three (3) yearsfrom the date of delivery that the goods sold are free f